SAMPLE COOLER Model: SWAS 06
Application
In-Line & Submersion
The New Model :SWAS 06 Sample Cooler
has been designed to cater to meet
sampling requirement of today's highly
efficient high-pressure power plants.
These coolers are compact yet more
effective in terms of heat extraction
capacity.
Very close approach temperatures with
minimal cooling water requirement.
A complete single piece coil assures
trouble free operations with no risks of
failure of joints inside the shell.
It's very compact compared with the
service it is put to. The double helix coil
design makes it's size almost half the size
of conventional single helix designs.
Facilitates routine on-site maintenance
easy. Coils can be cleaned in-place.
Specifications for Sample Cooler
Sample Coil :
> Material : Stainless Steel ASTM A 213, TP 316
> Design Pressure : 250 Kg/Cm2
> esign Temperature : Maximum 560° C
> Tube Size : 1/4" OD, 20 SWG
> Test Pressure (hydrostatic) : 375 Kg/Cm2
Installation Data :
> Sample (Inlet / Outlet) : ¼” OD Pipe
> Cooler (Inlet / Outlet) : 1/2" NPT (Female)
> Cooler flow rate at max: 800 Ltr/Hr.
> Shell test process : 10 Kg/cm²
> Max cooler process : 7 Kg/cm²
Shell:
> Material : Stainless Steel ASTM A 240, TP 304
> Design Pressure : 10 Kg/Cm2
> Tube Size : 360 mm OD (No ERW joints)
> Test Pressure (hydrostatic) : 15 Kg/Cm2
End Connection :
> Sample (Inlet / Outlet) : Double ferrule compression
fittings for 1/4" OD Tube
> Cooling Water (Inlet / Outlet) : 1/2" NPT (F)
> Shell Relief Valve : Double ferrule
|
Download Complete
Information (PDF)
|